91 research outputs found

    Využití sériového rozhraní glukometrů nevidomými

    Get PDF
    Many of the personal diagnostic systems mainly glucometers (for measuring glucose) contain a serial interface for PC connection. Through this interface it is possible to receive useful data that will be used mainly for an attending physician’s purpose to evaluate the treatment process over a long time period and to set down further treatment procedures. For purblind or sightless diabetics people it is impossible to read the current data showed on displays of the personal diagnostic systems. Those who are sightless need a help of another person at disposal when measuring. The newly designed unique electronic construction in conjunction with the personal diagnostic system enables a purblind or a sightless people to identify measured data and use them suitable for the further treatment processes. The purblind or sightless people will be able to perform selfmonitoring (observation of disease trend and a dosage adjustment by a person himself)

    A model transformation framework to increase OCL usability

    Get PDF
    The usability of a modeling language has a direct relationship with several factors of models constructed with the modeling language, such as time required and accuracy. Object Constraint Language (OCL) is the most prevalent language to document system constraints that are annotated in the Unified Modeling Language (UML). OCL is reputed as a modeling language with difficult syntax, and prior knowledge of OCL is needed to use the language. These obstacles result in the low usability of OCL. Therefore, the current research proposes a model to automatically transform system constraints formed in English sentences to OCL specifications. The proposed model is based on the Model-Driven Architecture (MDA) approach. The Linear Temporal Logic (LTL) properties of the proposed model are verified by the Maude model checker. To validate the proposed model and compare it with the existing work, the En2OCL (English2OCL) application is developed. This application is tested by three evaluation metrics: precision, recall, and f-measure. The En2OCL application is further compared with the NL2OCLviaSBVR application, which is the existing work on OCL generation from English sentences. The comparison shows a considerable improvement in precision, recall, and f-measure.Web of Science281261

    The evaluation of light conditions influence and corrections upon Doppler blood perfusion imagining

    Get PDF
    The paper deals with theoretical and experimental research of the ambient light influence upon the measuring reliability of the perfusion maps by the laser Doppler method using the device PeriScan PIM 3. The main applicable result of the analysis is a set of recommendations for the standardization, the improving of reliability and the compactness of the blood perfusion measuring in the clinical practise. The improvement of examination brings more accurate results and contributes to the optimization of diagnostic process and therapy

    Segmentation of articular cartilage and early osteoarthritis based on the fuzzy soft thresholding approach driven by modified evolutionary ABC optimization and local statistical aggregation

    Get PDF
    Articular cartilage assessment, with the aim of the cartilage loss identification, is a crucial task for the clinical practice of orthopedics. Conventional software (SW) instruments allow for just a visualization of the knee structure, without post processing, offering objective cartilage modeling. In this paper, we propose the multiregional segmentation method, having ambitions to bring a mathematical model reflecting the physiological cartilage morphological structure and spots, corresponding with the early cartilage loss, which is poorly recognizable by the naked eye from magnetic resonance imaging (MRI). The proposed segmentation model is composed from two pixel's classification parts. Firstly, the image histogram is decomposed by using a sequence of the triangular fuzzy membership functions, when their localization is driven by the modified artificial bee colony (ABC) optimization algorithm, utilizing a random sequence of considered solutions based on the real cartilage features. In the second part of the segmentation model, the original pixel's membership in a respective segmentation class may be modified by using the local statistical aggregation, taking into account the spatial relationships regarding adjacent pixels. By this way, the image noise and artefacts, which are commonly presented in the MR images, may be identified and eliminated. This fact makes the model robust and sensitive with regards to distorting signals. We analyzed the proposed model on the 2D spatial MR image records. We show different MR clinical cases for the articular cartilage segmentation, with identification of the cartilage loss. In the final part of the analysis, we compared our model performance against the selected conventional methods in application on the MR image records being corrupted by additive image noise.Web of Science117art. no. 86

    Pomiar parametrów elektrycznych i testowanie implantowanych cardio-stymulatorów

    Get PDF
    The aim of the work was measurement and testing of implantable cardioverter - defibrillator (ICDs) device. There was realised electronic measuring circuit which substitutes human body tissue during the device accuracy testing. This circuit enables to measure defibrillation shock discharge in the whole energy range (0.1- 41J). The presented measuring and testing procedures can easy check-up precision of parameters and functionality of embedded electronic device circuit’s part of the ICDs. Presented suggestion and results of this work can be implemented as verification procedure in various types of ICDs and also pacemakers before their implantation as well.W artykule przedstawiono wpływ indukcji i częstotliwości na straty w żelazie w blachach elektrotechnicznych wykorzystywanych w dławikach pracujących w filtrach wyższych harmonicznych. Podano uogólnioną zależność pozwalającą na obliczenie strat histerezowych i wiroprądowych z uwzględnieniem zastępczej eliptycznej pętli histerezy. Otrzymane wyniki porównano z pomiarami. Wprowadzony do rozważań współczynnik An zależy w praktyce od średniej wartości indukcji występującej w przekroju poprzecznym rdzenia. Uogólniona zależność zawierająca współczynnik An może być stosowana w szerokim zakresie częstotliwości

    Design and development of a novel Invasive Blood Pressure simulator for patient's monitor testing

    Get PDF
    This paper presents a newly-designed and realized Invasive Blood Pressure (IBP) device for the simulation on patient’s monitors. This device shows improvements and presents extended features with respect to a first prototype presented by the authors and similar systems available in the state-of-the-art. A peculiarity of the presented device is that all implemented features can be customized from the developer and from the point of view of the end user. The realized device has been tested, and its performances in terms of accuracy and of the back-loop measurement of the output for the blood pressure regulation utilization have been described. In particular, an accuracy of ±1 mmHg at 25 °C, on a range from −30 to 300 mmHg, was evaluated under different test conditions. The designed device is an ideal tool for testing IBP modules, for zero setting, and for calibrations. The implemented extended features, like the generation of custom waveforms and the Universal Serial Bus (USB) connectivity, allow use of this device in a wide range of applications, from research to equipment maintenance in clinical environments to educational purposes. Moreover, the presented device represents an innovation, both in terms of technology and methodologies: It allows quick and efficient tests to verify the proper functioning of IBP module of patients’ monitors. With this innovative device, tests can be performed directly in the field and faster procedures can be implemented by the clinical maintenance personnel. This device is an open source project and all materials, hardware, and software are fully available for interested developers or researchers.Web of Science201art. no. 25

    INFLUENCE OF THE USE OF GRAVITY SETS IN A PRESSURE VOLUMETRIC INFUSION PUMP WITH AN IMPACT ON THE ACCURACY OF INFUSION SOLUTION FLOWS

    Get PDF
    The subject of the work was the experimental verification of the negative influence of gravity sets in a pressure volumetric infusion pump with an impact on the accuracy of infusion solution dosing. The quality criterion for gravity sets was the accuracy of the flow versus the reference set by the volumetric infusion pump. The solution consisted of 14-hour measurements with two types of gravity sets, Intrafix® Primeline sets were used as universal sets and Standardline IS‑103 gravity sets. The insulin pump flow rate was set at 300 ml/h and 50 ml/h, and the actual flow rate of the infusion solution was recorded every hour using a graduated cylinder. Used gravity sets were also processed by mechanical tests, unused sets were subjected to these tests and the obtained data were compared with each other. Experiments carried out showed that at the set flow rate of 300 ml/h, the flow error with the universal set was -3% and at a set flow rate of 50 ml/h the error was +2.3%. Flow accuracy using gravity sets was worse, a flow error of -7.2% was detected for a flow rate of 50 ml/h and a flow error of -7.7% was measured for 300 ml/h. The volumetric pump used declares a tolerated inaccuracy of ± 3% when used with standard infusion sets. Based on the data, it can be concluded that the replacement of set types has an influence on the dosage of infusion solutions

    The potential of medical device industry in technological and economical context

    Get PDF
    The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union's macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.Web of Science111514150

    Review of processing pathological vectorcardiographic records for the detection of heart disease

    Get PDF
    Vectorcardiography (VCG) is another useful method that provides us with useful spatial information about the electrical activity of the heart. The use of vectorcardiography in clinical practice is not common nowadays, mainly due to the well-established 12-lead ECG system. However, VCG leads can be derived from standard 12-lead ECG systems using mathematical transformations. These derived or directly measured VCG records have proven to be a useful tool for diagnosing various heart diseases such as myocardial infarction, ventricular hypertrophy, myocardial scars, long QT syndrome, etc., where standard ECG does not achieve reliable accuracy within automated detection. With the development of computer technology in recent years, vectorcardiography is beginning to come to the forefront again. In this review we highlight the analysis of VCG records within the extraction of functional parameters for the detection of heart disease. We focus on methods of processing VCG functionalities and their use in given pathologies. Improving or combining current or developing new advanced signal processing methods can contribute to better and earlier detection of heart disease. We also focus on the most commonly used methods to derive a VCG from 12-lead ECG.Web of Science13art. no. 85659

    PREMATURE INFANT BLOOD VESSEL SEGMENTATION OF RETINAL IMAGES BASED ON HYBRID METHOD FOR THE DETERMINATION OF TORTUOSITY

    Get PDF
    For the retinal blood vessels segmentation, we used a method, which is based on the morphological operations. The output of this process is extracted retinal binary image, where is situated main blood vessels. In this paper is used dataset of images (2800 images) from device RetCam3. Before applying the image processing, it was selected 30 images with diagnosed pre-plus diseases, and it is divided into two groups with low contrast and good contrast images. In the next part of the analysis, it was analyzing and showing blood vessels with tortuosity. Tortuosity is a symptom of ROP (retinopathy of prematurity). The clinical physicians evaluate tortuosity by visual comparison of the retinal images images. For this reason, it was suggested model which can automatically indicate the tortuosity of the retinal blood vessels by setting a threshold of the blood vessels curvature